I have a Frigidaire Gallery series GLEQ2152ES electric dryer it turns on then turns off after 10-15 minutes and does not produce any heat. I did a diagnostic test and received an error e56 on the front panel. Please Help!

Judy for Model Number GLEQ2152ES

ANSWER Hello Judy. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Measure voltage across terminals on relay RL2 (heater relay) on electronic control. If meter reads 240V on electric models and 120V on gas models, replace electronic control. If meter reads zero, remove power from dryer. Disconnect wire going to NO terminal on the relay RL2. Reconnect power and measure voltage drop between terminal COM on relay RL2 and neutral. If meter reads zero, wire between incoming line and relay RL2 is open. If meter reads 120V, check the rest of the heater circuit. 