Both the right front dual element and the left front double element seem to have lost thermostat control. They do work but the temperature control is not useable. For example, you can completely burn an egg on a setting of 1.5 on the left front burner but on the right setting of 5 may only warm the pan. The same setting does not repeatably produce the same heat on either burner. Is the thermostat integrated into the heating element requiring replacement of the whole element or is there a way to replace only the thermostat?
Ray for Model Number Frigidaire PLES389ACC
ANSWER Hi Ray. The Lt. Front infinite switch is part # 318191002. The RT. front infinite switch is part # 318191002. If you are not getting 240 vac output from the switch at the H-2 and L-2 on the low mid and high settings, you have a defective switch. Thank You.
Answered by AppliancePartsPros.com | Wednesday, November 30, 2011