Fridge is cool, 48 degrees while the freezer is maintaining ice. Compressor & freezer fans working. Noticed ice building up on back of fridge temperature control. Water is collecting daily under bottom draws.

Fred for Model Number GE tbx18daxprww

ANSWER Hello Fred. It sounds like the drain is clogged and It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the evaporator coils in the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html 

Answered by AppliancePartsPros.com   |   Friday, October 18, 2013