My freezer is keeping food frozen but refrigerator part below is not keeping things cold. I have ice on back wall of freezer and water drips on top of refrigerator part down below.

Susan for Model Number tbx19za or tbh19za

ANSWER Hello Susan. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the back wall of the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Also, check and see if the drain on the unit is clogged. 

Answered by AppliancePartsPros.com   |   Tuesday, April 16, 2013