My Duet Whirlpool washer stops half way through almost every cycle with an F02 code. If I hit stop and start real quick the cycle will most of the time keep going and finish without a problem (other times it resets the cycle but then, still finished without issue). Very annoying. I put it into diagnostic mode and it gave an F-02 in part 6 of the cycle (expected), but then I ran it a couple more times and it worked fine. Checked for cloggs in the drain pipe and drain filter. Checked for 15 ohms on drain pump and it was replaced about 1 or 2 years ago for this same issue. Could this be a bad CCU? Does this go bad often? I would hate to spend $200+ if this is not the fix. Any advice is appreciated. Thank you!! JZ

Jz for Model Number GHW9100LW2

ANSWER JZ, Make sure that you also check the pressure hose to make sure that it is not clogged and check the hose coming off the bottom of the tub to make sure that it is not clogged. If either are clogged it could cause longer drain. If these check ok then you would want to replace the pump 280187

Answered by AppliancePartsPros.com   |   Wednesday, April 03, 2013