Maytag Dishwasher Model # MDBH985AWS Control Brd # W10111823 Reported: CB opened.at some point during DW cycle. Breaker reset.
No lights or functionality on DW. Power has been traced to the Control Brd. No obvious problems on either side of the Control Brd.
Would appreciate additional trouble shooting suggestions to isolate the problem.
Assuming the brd is fried, any suggestions on how to determine the root cause so we don't fry a replacement brd?
Thanks!
Snow M. for Model Number MDBH985AWS
ANSWER Hello Snow,
If you have power to the control board W10218831 and no power out of it, the board has failed. I would check the heating element and the motor for resistance before re-introducing power to the unit to avoid shooting the new board. I would also check the polarity and the wire nuts in the power connection box to make sure no problems exist there.
Answered by AppliancePartsPros.com | Tuesday, January 08, 2013