Is there a test for the EOC to be sure it is defective? I get an Error F30. I tested the probe and the resistance was at 1083 at room temperature.
Leon for Model Number FED367CEBC
Answer Hello Leon,
The resistance for room temp of 75 degrees is 1091 plus or minus 5.3. It sounds like it is within range so the next thing you want to check is the wiring from the sensor back to the EOC. Check your resistance at the EOC and see if you are getting the same reading. If not then you have bad wiring if you get the same reading then you will need to replace the EOC 318012914.
I need a new conrtol pad COVER... the unit is fine... it's just the black cover with the circles showing where to touch.
Shirley for Model Number FES367CEBE
Answer Hello Shirley. Sorry, but to replace the overlay, you have to replace the clock assembly 318012914. It is not available separately.