On my refer I need to know how many times the the control defrost timer goes around in 24 hours time period?
also the wires on the wires on the Heater Harness Def assembly what should the amps be?
Thank you I think my harness is ok because i replaced the harness about months ago.
I have got some good info in the past from you
Thank You
Paul
Paul Chirpich for Model Number TFK20JABKww
Answer Paul, It doesn't work that way, The defrost timer advances intermittently Based on when the compressor runs, after the timer has accumulated 8 hours of run time on the timer, it will advance into the defrost cycle which usually last for 26 minutes. If conditions are optimum, the timer may advance one revolution in a 24 hour period. We would expect an amperage draw of 4 to 5 amps maximum when the heater is energized in the defrst cycle. Good Luck and Thanks