No heat, replaced heating element assembly. Is it the thermal limiter?
Chris for Model Number GE electric dryer dvl223eb4ww
Answer Hello Chris. Check and make sure you have 240 volts coming to the dryer. Check and make sure the unit is not set to Air Fluff. Also check the thermostats and see if they are good. You can test these with a multi-meter TJMA-DM1. They should read closed for continuity. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html
Can a thermal limter switch be tested with an ohm/voltaga tester and where is it located.
Thomas for Model Number DCL333A0WW
Answer Hello Thomas,
You can check continuity of the thermal limiter using an ohm/voltage tester. The thermal limiter is located on the upper right rear of internal cabinet. When checking for continuity the limiter should be closed. If open then it needs to be replaced.