My Maytag dryer display did not respond when we pushed any button. And now it does not work.
Morad M. for Model Number MDG5500AWW
Answer Hello Morad. Test the high limit 33002567 and make sure it is closed and the door switch is working properly. If so, and none of the bottons are working, replace the console assembly 22004444. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. Hope this helps. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html
Hi,
My Maytag gas dryer, Model MDG5500AWW has been coming on all by itself and beeping. I ran the membrane pad check and all the lights came on, but I also got an initial code of 8.8 when I entered this memberane pad check mode. As I toggled each light off, they all went off except the signal+ light, which when pressed changed the code to 8. and that light did not go off. The signal - button turned that light off. Also, when I did the diagnostic code check, I got a code of 8, even though I had previously gotten this code and cleared it in a prior check. Can you tell me if the the LED console assembly (cover with membrane pad integrated) or the control board is the problem?
Thanks,
Nick
Nick for Model Number MDG5500AWW
Answer Hello Nick . The code 8.8 mean to change the control board 33003028. The LED console should be good, if it passed the test. Hope this helps.