Runs forever won't dry in automatic cycle. I cleaned the vent and ductwork.
Is problem the special thermostat or moisture-sensing system?
Joe for Model Number dv306lgw/xaa
Answer Hello Joe. You will need to test the thermostats and the flame sensor 338906 and make sure they are good. They should read closed for continuity. Also, check the igniter 33002789 and make sure it is getting hot enough to light the gas. Here is a link on how to use a multi-meter for the testing procedures. Hope this helps. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html