My oven and broiler won't light, when I turn them on I hear and see the stovetop ignitor spark? I can light them manually. I changed the oven ignitor with the same results
Tom for Model Number KGRA806PSS00
Answer Tom, based on your post, check and make sure the manual oven shut off valve is open(pointing up) and you can see the word"ON" stamped on the top of the valve body 9763716. If that is correct, you will need to check the resistance of the gas valve solenoids and low DCV to the gas valve from the DSI spark module W10331686, with a multi meter and the wiring for loose connections.Here's a little help " First thing, check and make sure the power cord is attached to a properly polarized and grounded 120 VAC outlet. A proper ground is very important for the range to operate properly. Then you'll need to make several tests at the gas distribution valve. You'll need a multi meter to test voltage and resistances. At the valve body terminals, with the wires labeled and remove from the middle terminal to each of the outer terminals, you should read 215 ohms resistance. With the wires reconnected, when you select the bake cycle, you should have a reading of 8 to 18 VDC across the red and orange wires. When you make a broil selection you should have the same 8 to 18 VDC,across the orange and blue wires. If all checks are proper(within 10%) replace the oven bake burner."