What should I be seeing for exhaust and heat tube temperatures.? The wifey seems to believe that our's runs too hot. And now the thermal fuse has opened? I have procrastinated as far as I can . ha ha
Chris for Model Number 110.97589210
Answer Hi Chris. You should regulate normally between 125-145/150°. It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Clean the vent hood / door flap outside also. The thermal fuse is part # 3390719. The flame senser is part # 338906, they will get sticky with plugged venting and cause the issue you explained. Thank you.
Dryer is not heating at its full capacity, clothes stay damp after cycle. What should I check first?
Sam for Model Number rgx6646aw2
Answer Hello Sam. It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Hope this helps.