What is the normal length of time it takes before the PTC relay resistance changes to an almost open circuit? Thanks
Rj for Model Number part # 2176806
Answer Hi RJ. The normal trip time for a ptc relay part # 10097204 is 4-6 seconds. It has a normal resistance value of 3-20 ohms. Thank You.
Can I disconnect from the compressor by just pulling on the part (don't want to break it) ? Also, does part 2183409 (physically above 2176806) plug into the compressor too or does it plug into part 2176806 ? Thanks
Rj for Model Number part # 2176806
Answer Hi RJ. Yes generally the ptc relay part # 10097204 does pull out from the compresor itself. Use a small screwdriver to pry the part out from the side of the compressor. The Overload Item Number: 2183409 pushes onto the compressor single pin first. Then the relay is placed over it holding it tightly on. Thank You.