I removed wires from relay and overload. Can you tell me where they go?
Ben for Model Number Msd2554ar
Answer Hi Ben. You can use the wiring diagram supplied within the control areas. The blue wire from the temp. control goes to the overload single connector. The # 3 relay connection is connected to the one side of the capacitor it is the S' side of the compressor. The #2 relay connector has the orange from the cond. fan. This same side of the relay has the other side of the capacitor and then goes to the R' terminal of the compressor. Thank You.