
{"id":13396,"date":"2024-12-30T12:24:51","date_gmt":"2024-12-30T20:24:51","guid":{"rendered":"https:\/\/www.appliancepartspros.com\/b\/?p=13396"},"modified":"2024-12-30T12:25:00","modified_gmt":"2024-12-30T20:25:00","slug":"how-to-fix-a-generator-pull-cord-that-wont-retract","status":"publish","type":"post","link":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/","title":{"rendered":"How to fix a generator pull cord that won\u2019t retract"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>Get your generator&#8217;s pull cord back in place with these easy steps so you can use your unit safely and as needed.<\/p>\n","protected":false},"author":3,"featured_media":13397,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_yoast_wpseo_focuskw":"how to fix a generator pull cord that won't retract","_yoast_wpseo_title":"%%title%% %%page%%","_yoast_wpseo_metadesc":"Get your generator's pull cord back in place with these easy steps so you can use your unit safely and as needed.","_aviaLayoutBuilderCleanData":"[av_image src='https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/Updated-blog-rectangle-13-1.jpg' attachment='13398' attachment_size='full' copyright='' caption='' styling='' align='center' font_size='' overlay_opacity='0.4' overlay_color='#000000' overlay_text_color='#ffffff' animation='no-animation' hover='' appearance='' link='' target='' title_attr='' alt_attr='' lazy_loading='disabled' id='' custom_class='' av_element_hidden_in_editor='0' av_uid='av-m52jv5f1' admin_preview_bg=''][\/av_image]\r\n\r\n[av_textblock size='' av-medium-font-size='' av-small-font-size='' av-mini-font-size='' font_color='' color='' id='' custom_class='' av_uid='av-m52jseb6' admin_preview_bg='']\r\n<!-- wp:paragraph -->\r\n\r\nImagine this scenario: you're all set to fire up your generator, but the pull cord just won't snap back. Annoying, isn't it? But hey, don't sweat it. I'm here to help you sort out that pesky cord and get your generator humming again.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:paragraph -->\r\n\r\n<strong><em>Heads up:<\/em><\/strong><em> The info here might not fit your exact generator model. Even though we're trying to share useful DIY repair tips, different models can have varying steps, error codes, parts, and so on. For the best advice, it's a good idea to check your manufacturer's manual or <\/em><a href=\"https:\/\/www.appliancepartspros.com\/repair-help\/\"><strong><em>reach out to us<\/em><\/strong><\/a><em> if you've got any questions.<\/em>\r\n\r\n[lwptoc numeration=\"romannested\"]\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading -->\r\n<h2 class=\"wp-block-heading\"><strong>Why won't the pull cord retract?<\/strong><\/h2>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nBefore we roll up our sleeves, let's figure out what's going on with that stubborn pull cord. Usually, it's either a worn-out starter rope or a busted recoil spring. Knowing what's causing the jam makes it way easier to fix.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>Common issues<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:heading {\"level\":4} -->\r\n<h4 class=\"wp-block-heading\"><strong>Starter cord frays<\/strong><\/h4>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nWhen the starter cord gets frayed or worn, it can get all stiff and not pull back in like it should. After a while, the rope fibers break down, causing it to catch inside the recoil mechanism.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":4} -->\r\n<h4 class=\"wp-block-heading\"><strong>Recoil spring loses tension<\/strong><\/h4>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nThat recoil spring is what makes the cord zip back after you pull it. If the spring's lost its tension or snapped, the cord's not gonna retract properly.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading -->\r\n<h2 class=\"wp-block-heading\"><strong>Gather your tools<\/strong><\/h2>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nLet's make sure you've got everything you need:\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:list -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul><!-- wp:list-item --><\/ul>\r\n<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li><strong>Flathead screwdriver<\/strong><\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li><strong>Lubricant<\/strong> (like Liquid Wrench)<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li><strong>New starter rope<\/strong> (same length and thickness as the old one)<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li><strong>Copper wire<\/strong> (optional, for threading the rope)<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li><strong>Safety gloves<\/strong> and <strong>goggles<\/strong><\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:paragraph -->\r\n\r\nIf you're not sure about the right kind of rope for your generator, it might help to <a href=\"https:\/\/www.appliancepartspros.com\/b\/how-to-find-your-appliances-model-number\/\"><strong>look up your model number<\/strong><\/a> to make sure you get the perfect fit.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading -->\r\n<h2 class=\"wp-block-heading\"><strong>Fix the pull cord step by step<\/strong><\/h2>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nAlright, let's get started. Here's how to fix that pull cord step by step.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>1. Put safety first<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nBefore you do anything, make sure the generator's off and unplugged from power sources. Toss on those safety gloves and goggles to keep yourself protected.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>2. Take off the generator cover<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nGrab that flathead screwdriver and undo the bolts holding the cover. Don't lose the bolts\u2014you'll need 'em when you're putting everything back together.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>3. Check out the recoil starter assembly<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nNow that the cover's off, you'll spot the recoil starter assembly\u2014that's the heart of the operation. Give it a good look-over for any obvious damage or gunk.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>4. Take out the old starter rope<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Find the knot or pin that's holding the rope inside the pulley.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Use your screwdriver to loosen and untie the knot.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Pull the old rope out from both the pulley and the handle. Sometimes you need to pry it out of the handle with the screwdriver.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>5. Prepare the new starter rope<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Line up the new rope with the old one to get the right length.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Trim the new rope if it's too long.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Singe the ends of the rope with a lighter or matches to stop it from fraying and make threading a breeze.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>6. Install the new rope into the recoil pulley<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Turn the recoil pulley counterclockwise about four times to get the spring nice and tight. Keep a firm grip so it doesn't unwind on you.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Line up the hole in the pulley with the rope guide hole in the starter housing.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Thread the new rope through the housing and into the pulley hole. If it's being stubborn, you can use some copper wire to help guide it through.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Tie a solid knot at the end of the rope inside the pulley.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Gently let go of the pulley so the spring winds the rope back in.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>7. Reattach the starter handle<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Feed the other end of the rope through the starter handle.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Tie a knot to keep the handle in place.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Make sure the handle's on tight and the rope pulls back smoothly.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>8. Lubricate the recoil assembly<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nGive the recoil assembly a quick spritz of lubricant. This cuts down on friction and helps everything run smoothly.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>9. Reassemble the generator<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Put the cover back on the generator.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Screw in those bolts you saved earlier.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Make sure everything's snug and lined up right.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>10. Test the pull cord<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nAlright, moment of truth:\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Take the generator outside to a well-ventilated spot.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Give the cord a pull to start up the generator.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>See if the cord snaps back smoothly after each pull.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:paragraph -->\r\n\r\nIf it's all working like a charm, congrats\u2014you fixed that pull cord!\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:heading -->\r\n<h2 class=\"wp-block-heading\"><strong>Troubleshooting tips<\/strong><\/h2>\r\n<!-- \/wp:heading --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>When the recoil spring is the problem<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nIf the cord's still acting up, it might be the recoil spring. Here's what to do:\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol><!-- wp:list-item --><\/ol>\r\n<\/li>\r\n<\/ol>\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Take off the recoil starter assembly from the generator.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Carefully open up the recoil spring housing\u2014watch out, the spring can pop out quickly.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Check if the spring is broken or has lost its tension.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>If it's busted, get a new recoil spring that fits your generator model.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ol>\r\n \t<li style=\"list-style-type: none\">\r\n<ol>\r\n \t<li>Put the housing back together, making sure the spring sits right.<\/li>\r\n<\/ol>\r\n<\/li>\r\n<\/ol>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading {\"level\":3} -->\r\n<h3 class=\"wp-block-heading\"><strong>Keep it running smoothly<\/strong><\/h3>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nTo keep things running smoothly down the road:\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:list -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul><!-- wp:list-item --><\/ul>\r\n<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Check the starter rope now and then for wear and tear.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Keep the recoil assembly clean\u2014no dirt or debris.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item --> <!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Give the moving parts some lube every so often.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list --> <!-- wp:heading -->\r\n<h2 class=\"wp-block-heading\"><strong>We're here to help<\/strong><\/h2>\r\n<!-- \/wp:heading --> <!-- wp:paragraph -->\r\n\r\nFixing a generator pull cord can feel a bit overwhelming, but with some guidance, you got this. And hey, if you need any parts or extra help, we're right here at <a href=\"https:\/\/www.appliancepartspros.com\/\"><strong>AppliancePartsPros.com<\/strong><\/a>. Check out our <a href=\"https:\/\/www.appliancepartspros.com\/repair-help\/\"><strong>repair help<\/strong><\/a> section\u2014it's full of stuff to help you out.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:paragraph -->\r\n\r\nStay in the loop for more tips and updates. Follow us on <a href=\"https:\/\/www.facebook.com\/appliancepartspros\"><strong>Facebook<\/strong><\/a> and <a href=\"https:\/\/twitter.com\/applpartspros\"><strong>Twitter<\/strong><\/a>.\r\n\r\n<!-- \/wp:paragraph --> <!-- wp:paragraph -->\r\n\r\nGot questions or need some one-on-one advice? Don't be shy\u2014reach out to us. We're here to make your appliance repairs go as smoothly as we can.\r\n\r\n<!-- \/wp:paragraph -->\r\n[\/av_textblock]\r\n\r\n[av_social_share title='Share this entry' buttons='' share_facebook='' share_twitter='' share_whatsapp='' share_pinterest='' share_reddit='' share_linkedin='' share_tumblr='' share_vk='' share_mail='' share_yelp='' yelp_link='https:\/\/www.yelp.com' style='' av-desktop-hide='' av-medium-hide='' av-small-hide='' av-mini-hide='' alb_description='' id='' custom_class='' av_uid='av-n7m5v8']\r\n\r\n","_aviaLayoutBuilder_active":"active","footnotes":""},"categories":[84,1266,495,194,8],"tags":[3803,269,666,3798,3796,3799,3801,3802,3800,3797],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\r\n<title>How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog<\/title>\r\n<meta name=\"description\" content=\"Get your generator&#039;s pull cord back in place with these easy steps so you can use your unit safely and as needed.\" \/>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_US\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog\" \/>\r\n<meta property=\"og:description\" content=\"Get your generator&#039;s pull cord back in place with these easy steps so you can use your unit safely and as needed.\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/\" \/>\r\n<meta property=\"og:site_name\" content=\"AppliancePartsPros Blog\" \/>\r\n<meta property=\"article:published_time\" content=\"2024-12-30T20:24:51+00:00\" \/>\r\n<meta property=\"article:modified_time\" content=\"2024-12-30T20:25:00+00:00\" \/>\r\n<meta name=\"author\" content=\"Steven E\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Steven E\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/\",\"url\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/\",\"name\":\"How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg\",\"datePublished\":\"2024-12-30T20:24:51+00:00\",\"dateModified\":\"2024-12-30T20:25:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/03ac441e1fde2369dc0cf9fdd27c07bc\"},\"description\":\"Get your generator's pull cord back in place with these easy steps so you can use your unit safely and as needed.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage\",\"url\":\"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg\",\"contentUrl\":\"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg\",\"width\":1080,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"APP Blog\",\"item\":\"https:\/\/www.appliancepartspros.com\/b\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Outdoor Power Equipment\",\"item\":\"https:\/\/www.appliancepartspros.com\/b\/category\/outdoor-power-equipment\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How to fix a generator pull cord that won\u2019t retract\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/#website\",\"url\":\"https:\/\/www.appliancepartspros.com\/b\/\",\"name\":\"AppliancePartsPros Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.appliancepartspros.com\/b\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/03ac441e1fde2369dc0cf9fdd27c07bc\",\"name\":\"Steven E\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/705340c7fffdf187ab647815aa35a88c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/705340c7fffdf187ab647815aa35a88c?s=96&d=mm&r=g\",\"caption\":\"Steven E\"},\"description\":\"With nearly a decade of experience in providing top-notch customer service regarding appliance parts and repair, Steven enjoys sharing practical advice, troubleshooting tips, and interesting information to help readers stay informed.\",\"url\":\"https:\/\/www.appliancepartspros.com\/b\/author\/stevene\/\"}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog","description":"Get your generator's pull cord back in place with these easy steps so you can use your unit safely and as needed.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/","og_locale":"en_US","og_type":"article","og_title":"How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog","og_description":"Get your generator's pull cord back in place with these easy steps so you can use your unit safely and as needed.","og_url":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/","og_site_name":"AppliancePartsPros Blog","article_published_time":"2024-12-30T20:24:51+00:00","article_modified_time":"2024-12-30T20:25:00+00:00","author":"Steven E","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Steven E","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/","url":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/","name":"How to fix a generator pull cord that won\u2019t retract - AppliancePartsPros Blog","isPartOf":{"@id":"https:\/\/www.appliancepartspros.com\/b\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage"},"image":{"@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage"},"thumbnailUrl":"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg","datePublished":"2024-12-30T20:24:51+00:00","dateModified":"2024-12-30T20:25:00+00:00","author":{"@id":"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/03ac441e1fde2369dc0cf9fdd27c07bc"},"description":"Get your generator's pull cord back in place with these easy steps so you can use your unit safely and as needed.","breadcrumb":{"@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#primaryimage","url":"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg","contentUrl":"https:\/\/www.appliancepartspros.com\/b\/wp-content\/uploads\/2024\/12\/APP-blog-square-10-2.jpg","width":1080,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/www.appliancepartspros.com\/b\/how-to-fix-a-generator-pull-cord-that-wont-retract\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"APP Blog","item":"https:\/\/www.appliancepartspros.com\/b\/"},{"@type":"ListItem","position":2,"name":"Outdoor Power Equipment","item":"https:\/\/www.appliancepartspros.com\/b\/category\/outdoor-power-equipment\/"},{"@type":"ListItem","position":3,"name":"How to fix a generator pull cord that won\u2019t retract"}]},{"@type":"WebSite","@id":"https:\/\/www.appliancepartspros.com\/b\/#website","url":"https:\/\/www.appliancepartspros.com\/b\/","name":"AppliancePartsPros Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.appliancepartspros.com\/b\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/03ac441e1fde2369dc0cf9fdd27c07bc","name":"Steven E","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.appliancepartspros.com\/b\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/705340c7fffdf187ab647815aa35a88c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/705340c7fffdf187ab647815aa35a88c?s=96&d=mm&r=g","caption":"Steven E"},"description":"With nearly a decade of experience in providing top-notch customer service regarding appliance parts and repair, Steven enjoys sharing practical advice, troubleshooting tips, and interesting information to help readers stay informed.","url":"https:\/\/www.appliancepartspros.com\/b\/author\/stevene\/"}]}},"_links":{"self":[{"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/posts\/13396"}],"collection":[{"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/comments?post=13396"}],"version-history":[{"count":2,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/posts\/13396\/revisions"}],"predecessor-version":[{"id":13511,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/posts\/13396\/revisions\/13511"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/media\/13397"}],"wp:attachment":[{"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/media?parent=13396"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/categories?post=13396"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.appliancepartspros.com\/b\/wp-json\/wp\/v2\/tags?post=13396"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}