1 Answer Mary, There would be a main control board and a Display control board. The part number for the main control board is 5304483065. Read More...
Steve July 15, 2016 for Model Number lra18hmu218 Hello my ac/ heating window unit will not turn on when I reset the plug on the wall everything lights up with two eights in the display is this my pc board
1 Answer Hello Steve. Yes, it sounds like the board is bad and will need to be replaced on the unit. Read More...
Skylerlulu May 15, 2015 for Model Number lra18hmu2 My 18.500 btu unit is stuck in heat mode. Even when I turn unit off with remote. It continues to run. No matter if I switch it to cooling or fan only. The heat cycle continues to run. Please help.
1 Answer Hello Skylerlulu. It sounds like the relay board is bad and will need to be replaced. You will need the last 2 numbers of the model number to know which one you will need to order. Read More...
Brenda M April 14, 2015 for Model Number LRA12HZU2 THIS # DOES NOT HAVE A 10 OR 11 AT THE END I have a Frigidaire window ac unit 12000 btu with heat. The compressor continues to run even when the unit is powered off. I believe it is a faulty PC board. Please advise.....help.
1 Answer Brenda, The cause for the compressor staying on even with the unit off would be a stuck relay on the control board which the board would need to be replaced. Read More...