David June 15, 2016 for Model Number DLGX3471V My gas dyer keeps running at the end of the cycle. Display goes off dry keeps running. If I start a new cycle the display lights up and operates like normal 1. its suggested it most likely to be the main Pcb assembly. 2.When I lookup on your website the part number AP5071654 that is listed for this model also says not compatible when you cross check. Any thoughts?
1 Answer David, The correct part for your main pcb would be EBR62707646 and would be the most likely cause for the issue. Read More...
Dale December 27, 2014 for Model Number DLGX3002 LG Gas Dryer DLGX3002 converted to LPG. In use 4 years. About 6 weeks ago found the resettable temp sensor popped. Reset it then replaced it a week later. A few weeks later dryer began to fire intermittently. Ignitor always heated up but intermittent starting. Found that gas valve had a flaky connection in coil on valve 1. Replaced gas valve. Dryer worked fine for a few weeks then began to fire intermittently. I then replaced flame sensor, hi-limit sensor and control board and it is still firing intermittently. Today after the new control board it started 12 times in a row, then worked fine for 3 loads of wash, then failed to start on load 4. When it fires the first time it always cycles on and off correctly re-firing as needed. The ignitor reads 156 ohms so I do not suspect a problem there. I ordered another gas valve just on the chance that the 1st one from APP is somehow defective but have not installed it yet because I think that is a real long shot. I have checked all the connections and they are tight. I have the service manual and I have been using the troubleshooting guide and the wiring diagram. Even though the parts I replaced were probably ok I have left the new ones in place for now. I am out of ideas. Someone with experience with LG gas dryers please give me any suggestions.
1 Answer Dale, The first thing that you will want to check is the venting. Check from the blower wheel to the outside of the home to ensure that there is no issue with a restriction or blockage. This is a main cause for misfiring of the burner when there is not proper air flow. Read More...