Paul for Model Number FGF337BCE I want to convert my LP stove back to natural gas. what do I need and do I have to do anything to the regulator? Thank you, Paul
Answer Paul, To convert your range back to Nat gas you will need the top burner orifices. The part numbers are for the left and right rear and left front 316237901, and for the right front 316237902. You will also need to loosen the oven orifices approximately 1 1/2 to 2 turns and open the air shutters. You would also need to flip the regulator cap from LP to NAT. Read More... Answered by AppliancePartsPros.com | Tuesday, December 17, 2013