Bill for Model Number TGF657BFB6 Looking for a conversion kit for a Tappan Range Model# TGF657BFB6. To convert from natural gas to LP. Is there a kit available for this range? Thank you
Answer Hello Bill. This model is convertible. You adjust the orifices and flip the regulator to convert the unit. 1. Lift cooktop to gain access to the surface burnerspuds.2. With ½" wrench, turn spud down or clockwise untilsnug (approximately 2 ½ turns). This restricts theflow of gas through spud to that allowed only by thehollow LP metering pin. Do not overtighten. 3. Lower main top and apply gas to check for properflame size. Flame should be steady withapproximately ½" blue inner cones and no yellow ororange tips. Proper Air AdjustmentIf air shutter is adjusted so that too much air flows intothe burner, the flame will appear unsteady, possiblynot burning all the way around and will be noisy (likea blow torch). Do Not Remove the Pressure RegulatorRemove cap-screw and snap out the nylon gasindicator by pushing it sideways. Turn the nylon gasindicator for type gas (Natural or LP) and snap it backin the cap-screw. Put cap-screw back on gasregulator. Read More... Answered by AppliancePartsPros.com | Friday, February 28, 2014