Answer

Wessam, your model does not have a defrost timer but uses an adaptive defrost control which is located on the main control board on the back of the refrigerator. If the heater is good, the problem will be with the defrost thermostat located on the top of the evaporator or the defrost control is not putting the unit into defrost. Look at the defrost thermostat, if there is a bulge at the top of it, it is bad and needs to be replaced. When it is cold, it should also read closed and have continuity. the part number for the thermostat is WR50X10065, the control board is WR55X10942C

Read More...

Answered by AppliancePartsPros.com   |   Tuesday, February 4, 2020

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google