John for Model Number AZ65H15DADW1 Hello, I have this GE unit. It is likely several years old, but was never installed. I installed it in my shop, hooked up the 240 volts. The unit turns on fine, but only the electric heat works. The compressor doesn't kick on for the heat pump. I tested the motor windings and also tested the capacitor, and it all checks out fine. Turns out the relay on the main board that is supposed to kick on and supply the second leg of the 120 volts to the capacitor isn't activating. I ohmed the coil side leads for the relay on the main board and they ohm good, but I don't get any voltage to the coil side of the relay. I did bypass the relay and jumper the other leg to the compressor and got it to run fine. Is there anything else I should look at control wise or is the main board likely the culprit? I don't know if any sensors or any other items would keep that contactor from engaging. Thank you
Answer John, Based on what information was provided, the main control board will be the most logical cause for this issue. Read More... Answered by AppliancePartsPros.com | Friday, November 24, 2023