Pj for Model Number 795.71023.010 Thanks for the help on this. I was about to test the inverter, plugged it in and it started to work like it's supposed to. Something like this happened a couple years ago when the fridge was left ajar when we went out of town for the weekend. I don't know if that was the case again, but seems coincidental. Is this a safety shut down? I'll keep an eye on it for now. If you could please let me know that would be great. I've attached the previous correspondence for reference. Fans are running, no compressor. Compressor was replaced 9 yrs ago after only being in service for 2 yrs. Relay RY201 on the control board is ticking like a clock and will not stop. LED not illuminated at all. Read a couple of other questions that were similar but need some more info. What series of checks can made to diagnose. I don't want to buy PC boards and not be the problem I am sure you understand that mess. Pj for Model Number 795.71023.010 Answer PJ, You can test to see if there is 120 Vac to the inverter board coming off the main control board. If there is not then the main control board will be the issue. If there is then the inverter would be the most likely cause. Whichever board is making the clicking will be the most likely cause for this issue.
Answer PJ, it is possible that it could have been a temporary glitch. However, the only sure way to identify the failure would be testing during the state of failure or identifying an error code. Read More... Answered by AppliancePartsPros.com | Monday, August 22, 2022