Charles K for Model Number mah6500awq I Disconnected the motor and checked oms on black and white terminals on the motor reading was 0 do you think the motor is OK? Thanks, CK
Answer Hello Charles. To test the motor WP22003856, you will check across blue and black, white and red, and orange and yellow. Each one should read between 2 to 3 ohms. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. Hope this helps. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More... Answered by AppliancePartsPros.com | Friday, September 23, 2011