Mark for Model Number GI15NDXTS2 Model GI15NDXTS2 SERIAL NUMBER E00304106 IS NOT MAKING ICE. 1. Turn unit on water enters into resvor. 2. After fill the water pump kicks on and transfers water to the top of frezzing plate water runs over freezing plate. 3. Water runs over freezing plate but ice slab never forms - freezing plate seems to be cold not sure if its cold enough. 4. does problem lie with in the main board? compressor ? or condensor ? 5. This unit is only 2 years old and water pump hs already been changed 6 What are you thouths
Answer Hello Mark. Check and make sure the condenser coils are clean and the fan motor is running properly. If so, and the unit does not freezer the water on the plate, you have a bad sealed system on the unit. It may be low on freon or restricted. Read More... Answered by AppliancePartsPros.com | Wednesday, May 9, 2012