Warren for Model Number Amana ARS9167AC Bottom of freezer below freezing, top of freezer at 60 degrees. Refrigerator also warm. Compressor runs fine and fan next to compressor also working. Tested the evaporator fan and the ohms are about 60 (is that the right ohm reading), turns easily but it seems to cut off too soon after plugging in the fridge after sitting for 30 minutes. Any idea what might be wrong? Could defrost timer be the problem? Thanks
Answer Warren, With this issue the most likely cause for this issue would be a fan that is faulty. Read More... Answered by AppliancePartsPros.com | Monday, October 2, 2017