Steve for Model Number MCG8000AWW What is wrong with Neptune dryer. Is it the control board of the relay board? This is a gas dryer. Start up top or bottom and after maybe 20 seconds it stops and say PF code which is power failure. No power failure has occurred from the house electricity. Then I press start again and will not start. Code window does not display anything and all the green lights on the front start flashing. Maybe faint green flickering in the code window. I then unplug the dryer and plug it back in after several minutes and still nothing in the code window and all the green lights flashing. It acts locked up. If I have it unplugged for a week then It will like reset and I can start it and then does the same thing after about 20 seconds. This problem has gotten worst started months ago could run dryer for around 8 minutes before this would happen. This problem started after about 1 1/2 years of use. I would like to first as dryer has very little usage and I liked it a lot.
Answer Hello Steve. Look for loose connections. If none is found, replace the relay board. If the issue continues after that, the logic board will need to be replaced per the manufacturer. Read More... Answered by AppliancePartsPros.com | Wednesday, February 26, 2014