Tom K for Model Number 3110PRW labeled Magic Chef 7 months ago i changed from gas to LP ussing 20gal gas from my grille. Had no prolems until a week ago i changed tanks and lit the pilos and it restarted fine. Then i went to use the stove to cook and pilots would not light. Tried th oved and nothing. Thought it was a bad tank of gas but tried it on grille and it started o.k. I have a pressure regulator at the tank and the one on the stove. Why won't it relight ?
Answer Tom, You'll need to test the pressure at the regulator on the tank. It needs to have a minimum of 10 WCI and a maximum of 14 WCI to the stove regulator WP7510P083-60. We take for granted you have properly converted the regulator and burner valves to the LP gas configuration. So you'll need to check the pressure at the top burner valve farthest away from the regulator, with all the burners on and operating and check for the same pressure at the burner, This will confirm whether the regulator is at fault or not. You'll need to access or make up a manometer to perform these tests. You may have "crud" in the supply lines and tubing from the tank interior. Read More... Answered by AppliancePartsPros.com | Thursday, June 27, 2013