Ed R for Model Number WFW94HEXW0 I'm getting error code F6E1,E2. have performed testing, door switch locks, but nothing after that. Took an ohm reading on DLS2 and had one ohms, and on DCS3 1 & 3, and also had one ohm. On DL3, I had 61 ohms on each combination. Could this be a faulty door switch interfering with MCU operation?
Answer Ed, The way that the door lock should read is from DCS3-1 to DCS3-3 with the door closed there should be continuity and with the door open there should be an open circuit. If you measure between DL3-1 to DL3-2 there should be 50 to 74 ohms of resistance and from DL3-2 to DL3-3 the resistance would be between 50 to 74 ohms of resistance. If you test from SLS2-1 and DLS2-2 with the door in the locked position there should be continuity and in the unlocked position should read open. Based on the testing that you checked it would sound like this door lock would not be the issue. With the error that you are having you would want to check the wiring between the user interface and the main control board and between the main control board and the CCU as the F6 E2 is a communication error. This issue with both error codes would likely be the main control that is at fault. Read More... Answered by AppliancePartsPros.com | Tuesday, September 13, 2016