Jon R. for Model Number ET19RKXGN00 >>If the unit is cooling, then the defrost timer is good. >>You will need to check the coils in the back of the >>refrigerator and make sure they are clean, and check >>the condenser fan motor to make sure it is running properly. The defroster heating element is staying on, but the unit is cooling fine. So the timer is not the issue. All we noticed is that if you touch the outside of the unit around where the defroster heating element is, it is VERY hot. Hot enough to burn your hand if you hold it there long enough. The defroster heating element is always on. Is this controlled in some way by the condensor motor or coils being dirty? I can check that, but it seems like there would be something else causing the defroster heating element to stay on. Or are you saying that it could be turned on because something is wrong with the condensor motor or the coil are dirty?
Answer Hello Jon. The defrost heater is located inside the freezer, behind the back wall, on the bottom of the evaporator coils. The condenser lines run through the frame of the refrigerator, not the defrost heater. They are suppose to get warm, but not too hot. If they are too hot, they are either dirty or the fan motor is not running. Hope this helps. Read More... Answered by AppliancePartsPros.com | Friday, June 10, 2011