Paul K. for Model Number Roper refrig RT18DKXJW01 by Whirlpool - small freezer on top, mfg. October 2000 The refrigerator section of Roper model RT18DKXJW01 is not cooling well recently. In the past, it has gotten too cold in back. One person guessed a bad defrost timer or defrost element. How would I decide which and do you figure problem may be something else?
Answer Hi Paul. Depending on the temperatures in each sections then you will have different scenarios. Is the defrost timer allowing 120vac to come to the defrost thermostat ? Allowing (when the def. thermostat is closed), the 120vac to allow the defrost heater to come on? Your system usually defrosts in 6, 8 hrs., for approximately 20-25 minutes. The defrost timer is part # W10822278. Thank you. Read More... Answered by AppliancePartsPros.com | Friday, July 8, 2011