Boomer for Model Number roper refrigerator model? My refrigerator keeps freezing in the top mounted freezer slowly and gradually. I thaw it but eventually it will do again causing the bottom box to get warm. I checked the defrost heater for continuity and have nothing. I guess that means I have a break in the heater. Would you say that is the problem? I know it still could be the t-stat or timer. Please let me know.
Answer Hi Boomer. You can manually advance your defrost timer to the "start " of the 25 min. defrost time. Then you should have 120vac sent from the timer to the defrost thermostat. Under normal (frozen) temperatures, the defrost thermostat should be closed sending the 120vac to the defrost heater. Approximately 75% of defrost failures in unit 7-8 yrs old have a bad defrost thermostat. If your heater and thermostat are open, then yes by all means if you are already in the evaporator area replace both. If you will supply us with your exact model # , then we will be glad to assist you further. Thank you. Read More... Answered by AppliancePartsPros.com | Tuesday, July 12, 2011