Max H. for Model Number GT22DMXGW01 12 year old Whirlpool R/F I am away from home for extended periods of time and due to age of fridge,I decided on some PMs. I changed out the defrost timer AP3110896 and connected the black wire to terminal #1. I have also changed out the overload/relay combination AP3108669.On the relay, the white wire was replaced on the side with the two lugs(run leg?) and the red wire was replaced to the single lug on the overload. I also noticed that this model compressor had no run capacitor. I observed that for the past three days, that the condensor fan is continually cycling at a 5 min. on/8 min. off period and that there is not much pitch on the fan blades. Both the freezer and fridge seem to be cooling adequately and the icemaker seems to be working properly. The start and run legs of the compressor ohmed out at 6.4 ohms each and the condensor fan at 190 ohms. My questions are: 1-Is this cycling normal or is something in failure mode? 2-Would it be to my advantage to install a run capacitor across the compressor start relay? 3-Are any other parts near the end of their useful life and need replacing? Many thanks for any and all suggestions. Max
Answer Hi Max. A compressor relay capacitor will allow the compressor to run in a more efficient manner and last longer. This is my opinion professionally speaking. Some models do not have them and it seems it has been in the last 5-7 yrs they have been more and more depending on the manufacture. They are elect. connected to the start and run terminals of the run relay. As far as the defrost timer is concerned, the #3 terminal has the white wire. The #4 terminal has the red wire. The # 1 has the orange wire (as the timer motor lead wire is normally connected there also). The # 2 terminal has a pink double wire going to it. If the unit is cooling fine, then all is well. The condenser fan and the evaporator runs along with the compressor running. The cold control regulates the run as long as the set point is not satisfied. As the defrost timer comes out of defrost , it may need to wait approx. 6 minutes for the defrost thermostat to reset (close) dwell time and then the compressor will kick in. Then it will allow the compressor to run and allow the cold control to be satisfied. Compressor capacitor will be part # WP4387764. A capacitor is designed to store voltage and discharge it at a predetermined rate. This being said it allows the lead and lag time of the compressor to become more closely in "electrical sine wave" with each other and be more efficient. Thank You . Read More... Answered by AppliancePartsPros.com | Tuesday, January 24, 2012