Evan for Model Number sav4655ewq In the last few wks., we changed out the Water Temp. Switch (your recommendation) and the Timer. We now have problems when first starting a load, the water continues to fill the tub and gets very close to overflowing. We stopped it so that didn't happen. Once we advance it to agitation, then it works fine, including the rinse cycle (which does not overflow). Thoughts?
Answer Hi Evan. While filling on the start of a normal cycle, if you unplug the unit during this process and water keeps flowing it needs changed. Now then if stops filling after the unit is unplugged, then it is a bad pressure switch. Pressure switch is part # WP27001203. It sounds like you did correctly bu blowing out the pressure hose towards the tub so you can dislodge any lint or debris that will make a pressure switch to "misread" also. Thank You. Read More... Answered by AppliancePartsPros.com | Thursday, December 22, 2011