Mark K Binghamton , NY June 03, 2017 Control module stopped working (there were no error codes) I pulled the unit away from the counter, and unplugged it. I backed out 6 screws on the door. The door front came off and I pulled off the trim. I then had access to the control module. I pulled several pin connectors and then replaced the control Module with the new one. It was very easy and only took about 20 minutes. Read More... 2 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Ken G Minneapolis , MN September 29, 2014 Appliance: Model SHX45MO5UC/50 Dw would not fill valve checked out okay but no voltage across valve leads Replaced control unit Read More... Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Adjustable Wrench, Screwdrivers
Mike D Shelby Township , MI January 18, 2020 Long running time and no heat for drying. Tested the heater coil...good continuity....the only thing left is the control module as it control the heater coil. Replaced the control module and problem was fixed. Read More... Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Pliers, Screwdrivers