Similar to other stories on here, the microwave was repeatedly tripping the circuit breaker, usually when opening the door. Plugged microwave into a different outlet/circuit, and problem traveled to that breaker, so definitely issue within the appliance. Turned out to be door interlock switch.
This model has 3 switches: 2 x AP4512903 (00617228, the Primary and Secondary interlock switches) and 1 x AP4512904 (00617229, the Monitor switch). It was only the Monitor switch that was defective, but I went ahead and replaced all of them, as well as the plastic Door Lock (AP4513044) which was developing some groove wear after 7 years of use (makes the door wobble a bit over time). For good measure I also replaced the plastic Lever (AP5263819, aka 00621573; this snaps inside the door lock and controls the bottom switch’s plunger).
So I essentially replaced the entire Door Lock assembly, for about $40. Took about half an hour (I took my time) and a Philips screwdriver. Pro tip: Take close-up photographs so you know where all of the wires from the control panel go. There was a helpful wiring and troubleshooting diagram folded up and tucked inside the control panel from the factory (nice surprise).
Testing notes: The top microswitch 00617228 should measure open (no continuity) from terminal to terminal until the plunger is pressed.
The middle switch 00617229 should measure CLOSED (with continuity) from terminal to terminal until the plunger is pressed.
The bottom switch 00617230 should measure open (no continuity) from terminal to terminal until the plunger is pressed.
Two screws hold the Vent Hood piece on; take that off to reveal one screw holding Control Panel in place. Remove that (carefully, don't yank any wires), then two screws hold the entire Door Lock assembly in place. Fairly easy to wiggle out; careful not to disturb the metal microwave shroud behind it. Overall, a fairly easy repair. Very happy with the results; working like a champ again. Super speedy shipping of the parts!