I replaced the cold control unit. My chest freezer was no longer getting cold and I saw the compressor was not running. I pulled the wire off of the cold control switch and tested it for power. There was power. I made a short jumper wire from an old extension cord and plugged it into both sides of the power source. The compressor immediately came on. I ordered the cold control switch from AppliancePartsPros.com and so far, it is working perfectly. Thanks: Paul S. H.