Replaced keypad membrane switch.
The hardest part was removing and replacing the front panel. This has to be removed to pass the wires through and terminate on the circuit board behind.
The switch membrane adheres to the panel so be sure to clean it with alcohol after removing the old part. Be careful when positioning the new membrane as once it sticks it cant be repositioned.