It took a couple of days but using the information I gleaned from watching videos on the topic I was able to determine that the main PCB (motherboard) was the source of the problem. I got distracted when I got the "vent plugged" diagnosis when running the installation test but I found a reference to that test using the difference in temperatures to make that determination I had no heat so it made sense that the test could, in fact, come to that conclusion. My vent line appreciated it as well because it's now super clean. To get past that diagnosis, I just left the vent line off the dryer and when the same (clogged) test result came up I figured I needed to look elsewhere.
For reference, my dryer gave NO codes or indication that anything was having a problem other than NO HEAT. I was able to find the factory service manual and that allowed me to better understand how the built-in tests were initiated and also a diagnosis sequence for me to follow. I was really bummed when the very first test failed (a voltage test) and it was on the main PCB... the most expensive part! But continuing through the remaining tests (mainly continuity/resistance tests) everything else appeared to be giving acceptable results. So I went ahead and ordered the PCB.
The PCB arrived and was easy to install. I turned the dryer on and after about 15 seconds, it blew flames! Hooray!