Manda S San Diego , CA July 20, 2018 Appliance: Frigidaire Refrigerator EI23BC80KS3 Upper refrigerator too warm but freezer stayed frozen around 10 degrees I hired a repair man to come diagnose the issue since I had never worked on a frig before. He took apart the freezer to access to the rear panel. Step one turn off the fridge and unplug it. Then remove the freezer door by the four hex screws on either side, lift up off of the support pins and set to the side. Remove the ice maker bin, the shelf basket completely with the side glides. Next remove the crossbar for the whole freezer drawer with the two screws on either end. Then if a soft ice cream bin is installed remove that - there is a plastic piece that sets it in place in the front left section that snaps into the top of the freezer. Once that is removed you'll have to remove the one freezer door glide by shutting it completely and then loosening the screws that hold it to the wall. Once lose you can pull the whole assembly forward and it'll will pop off leaving the screws still in the wall. Remove the bottom plastic baffle by lifting up and out. Next remove the screws to the back metal panel and pull out from right to left. Disconnect the grounding clips and ice maker connection over on the left hand side. Now you'll test the defrost heater which runs along the bottom of the coils. if your coils are completely frosted over its either the heater or the Control board. You can test the coil by setting a multimeter to the lowest Amp setting and detecting if a current can run from end to end. If it doesn't show a reading then it's bad and you should replace. if it shows a reading then leave it installed and replace the Control board. Control board is located underneath the fridge right under the front of the freezer. It's a rectangular white box with one hex screw holding it to the fridge. have a friend lean and hold the fridge or set it on some blocks. Take out the one screw, then remove the black plastic cover where the wiring is inserted. Then disconnect the two connectors inside the box and replace. It's an easy plug and play, replace black plastic cover, replace control until to underside of the fridge. this whole process took about 5 mins if you already have the freezer door off. If your coils were completely frosted over then allow the frig to completely defrost with all the doors ajar, then after 24 hrs turn the fridge back on and let it run as usual. It might take 24 hrs for it to regulate again. Enjoy. Read More... Do-It-Yourself Rating: Repair Time Estimate: 1-2 hours Tools: Adjustable Wrench, Nut Drivers, Pliers, Screwdrivers, Socket Set