Shenton O Seattle , WA June 05, 2015 Controller board bad Bought a new upgraded unit from A.Pros. Perfect match with a history of going bad. Plugged it in and stove top ventilator works again Read More... 5 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Screwdrivers
David P Sarasota , FL June 11, 2019 Appliance: Model AVC48L1SS Range hood inoperative I ordered a control box, but that turned out not to be the problem, so I returned it. I then ordered, and installed a main circuit board, which fixed the issue. Anyone who attempts this repair should take several pictures of what plug goes where, in detail. before taking anything apart. There are a couple of plugs that can be incorrectly placed, if care is not taken. I marked my plugs before removing them from the old circuit board, as to their location (top, bottom, left, right, etc). Take care when disconnecting the plug in's from the main board, as the insulators can be broken if excessive force is used. There are 2 plastic wire "keepers" inside, at the top of the main board's box. They hold back the wires, so the plastic cover can be installed. You'll need to remove these 2 "keepers" to disconnect/reconnect the electrical plug in for the main board. After removing these "keepers", you can easily move the wires/plugs around to disconnect/reconnect them. Make sure to trip the breaker in the main electrical box before attempting the repair. There is also an on/off switch up inside the range hood itself. turn it to the off position before attempting the repair. Read More... 4 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Nut Drivers, Screwdrivers
David S Berwick , LA April 07, 2019 Main board went out. Replaced the main board. Read More... 1 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Gail W Birmingham , AL January 19, 2020 Appliance: General Electric Electric Range ZVC30L1SS Fan and light on GE monogram vent hood became problematic. Our GE Monogram range hood is 12 years old. A problem developed suddenly a few months ago when light and fan suddenly quit working completely. Called GE and the repairman could not fix it ... said I needed to buy a new vent hood. My hood has custom cabinets built around it, so I did not want to do that without trying to repair the electrical problem. I called an electrician who came out and found a simple loose wire. He had it working again within 20 minutes. Six months later it suddenly started acting up, coming on and off, on and off, on and off, etc. I had to flip the circuit breaker to get it to stop. Called an electrician and after doing a thorough examination, checking fuses, etc., he determined that the circuit board had gone bad. We were able to determine the part # on the circuit board, ordered it from AppliancePartsPros.com. We received the part in 2 days. Electrician installed it. Hood is working perfectly now. It was NOT a GE repairman. It was an self-employed electrician who diagnosed the problem, helped us locate and order the part, and ultimately fixed the problem. Note: I did not repair the problem myself, but relied on an experienced electrician. Read More... Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Howard H Fairhope , AL May 23, 2020 Appliance: Model ZVC36L1SS - GENERAL ELECTRIC HOOD Main control board failed most likely due to lightning/ Replaced the Main board. The Difficult part was finding a good way to sit on the Range Top to initiate and complete the repair. The work was very straight forward - photographed the old board before removal to insure I remembered where all of the connectors went on the replacement. Read More... Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Nut Drivers, Screwdrivers