Dan S Joshua , TX August 23, 2021 Compressor would keep running New PCB main assembly. Read More... 5 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
David G Boaz , AL April 12, 2023 Appliance: Model LW1816 HR The heat and ac quit same at the same time. The appliance repairman said it had to be the board. .Excellent salesperson helped me get the right part # and we received it in 2 days. I learned how to remove the board and replaced it. Works !! Read More... Do-It-Yourself Rating: Repair Time Estimate: 2+ hours Tools: Pliers, Screwdrivers
David N Mt Juliet , TN April 02, 2022 Appliance: LG Room Air Conditioner LW1815HR/00 The control panel unresponsive. The heat on continuously 1.Unplug the unit, Removed the vent cover, 2. Remove small Phillip screws on top of control panel holding vent oscillator. Then remove the plastic vent connector. 3. Remove the screws.Slide-out until the control panel side plate is exposed. 4. Side plate has two Philip screws at the bottom holding the control panel, remove. 5. Flip up side plate and push toward window mount to remove plate. 6. The control panel should slide out enough to unplug the board plug and power connector by pressing lock tabs to remove. 7. Carefully make note of the remaining wires. Label with tape or take pictures. Carefully unplug the ribbon cables by pressing lock tabs to remove them. 8. Remove the thermostat sensor from the plastic mount. 9. Carefully unplug all single wires with needle-nose pliers. 10.Remove the control panel box. 11.Remove the one screw that holds the circuit board. Slide-out and replace. 12. Before reversing all instructions to complete repair, install to a safe point to power up unit to test. If it works, complete assembly, if not check all connections. Good luck. Read More... Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Pliers, Screwdrivers