Craig June 14, 2023 for Model Number B22CS80SNS/01 My Bosch refrigerator compressor does not run I have two volts DC to the inverter board and the proper voltage everywhere else. The compressor ohms out good (7ohms) it is not shorted to ground. Any help with this would be greatly appreciated.
1 Answer Craig, This issue would be a faulty inverter board and will need to be replaced. Read More...
Melissa June 14, 2023 for Model Number B22CS30SNS/02 Both part control boards are called control modules, which one is the invertor for my compressor?
Bill June 14, 2023 for Model Number B22CS50SNB/03 My compressor is not running, How do I test this invertor control to see if its what has failed?
1 Answer Bill, You will test to make sure that there is 120 vac going into the inverter board and then on the smaller wires test for 4 to 6 vdc to the main board. Read More...
Mohammad April 26, 2018 for Model Number 00647583 (AP4397817) Bosch Refrigerator Control Unit Are you shipping the parts (Bosch Refrigerator Control Unit) in Canada?
1 Answer Hello Mohammad, I'm sorry but we do not have the capability to ship out of the US at this time. Thank you for your patience and understanding in this matter. Read More...