1 Answer Bill, This will need to be checked with a multimeter and the tech sheet packaged with the machine. Check the door switches and for power in and out of the control. Read More...
1 Answer Anthony, There would only be one of these switches on the unit and would be the center switch on the switch holder. Read More...
Gus May 16, 2023 for Model Number HF36V305/01 How do you go about testing to see if this part is faulty?
Gus May 16, 2023 for Model Number HF36V305/01 How do you go about testing to see if this part is faulty?
2 Answers Gus, You are wanting to make sure it changes from open to closed when the red switch is pressed. Place your meter to a continuity setting with one lead on each terminal and press the switch. Read More...
Gator May 16, 2023 for Model Number MEMC301ES01 When my door is open the unit will start running. Is this the part that would fix this?
2 Answers Gator, It is possible that you have a bad switch, but you will need to test the switches for continuity and replace them as needed. Read More...
Gator May 16, 2023 for Model Number MEMC301ES01 When my door is open the unit will start running. Is this the part that would fix this?
2 Answers Gator, This switch is responsible for reading whether the door is open or not. So yes, there's a good chance this is your problem. Read More...