Emmett April 17, 2020 for Model Number E32AR75FPS0 Electrolux Icon refrigerator Ice forms on the evaporator. Tested the heater-defrost element. It OK and the resistance is 35 Ohms. Tested the thermostat, defrost and works fine. The voltage coming to the heater is 40 Volts. I suspect the controller is bad. Should I change the controller (item number 216954210)? Thanks in advance.
1 Answer Emmett, based on the information provided, the failure would be in the main control 297334200. Read More...
Michael October 17, 2018 for Model Number FPRH19D7LF1 My fridge is set at 33 degrees the readout on the control module will say 33 for a time then jump up into the 50's, then go back to 33. I can tell it's getting warmer inside the unit. I have replaced the following: control unit, thermistor, capacitor, defrost switch, defrost element. Any assistance you could give me would be great.
1 Answer Michael,When your temp is on the rise you need to make sure compressor is still running and evaporator fan and condenser fans still running. Read More...