HI Eric. Thanks for the detailed explanation. The flashlight test was a good idea, and it sounds like you've narrowed the problem down to the ice dispenser chute door.
On your Frigidaire FPHS2699PF4A, the flapper should close firmly against the ice chute opening to prevent warm, humid room air from entering the freezer.
Since you've already replaced the dispenser assembly and are still getting frost, I wouldn't recommend replacing another assembly just yet.
Here's what I'd check first.
1. Check the flapper alignment
- Remove the ice bucket so you can inspect the chute from inside the freezer.
- Make sure the new flapper sits evenly against the opening.
- Look for any gaps around the edges, especially at the top.
- Check that the flapper isn't catching on the housing or sitting slightly crooked.
2. Check the closing mechanism
Press the ice dispenser paddle and release it.
The flapper should open and then return fully to its closed position.
If it doesn't close completely, check whether the return spring, linkage, or dispenser actuator is preventing it from seating properly.
3. Inspect the sealing surface
Even with a new flapper, the seal can leak if the surface it presses against is warped, cracked, dirty, or uneven.
Check for frost buildup, debris, or damage around the chute opening.
You can also gently press the closed flapper toward its sealing surface while repeating your flashlight test.
If the light disappears when you apply gentle pressure, that strongly suggests the flapper isn't being held firmly against the opening.
4. Check the replacement assembly
You mentioned that the new assembly looks different from the original.
That's worth investigating. Sometimes a replacement part has an updated design, but we need to make sure it's the correct replacement for your specific model.
Don't try bending the flapper or adding adhesive weatherstripping yet. That could interfere with the dispenser operation.
5. Verify the replacement part
The parts diagram for your model lists dispenser module 242270101, which has been superseded by 242270107. The replacement may look different from the original, so that alone doesn't mean it's incorrect.
Sears PartsDirect+1
If the flapper is aligned correctly but still allows air through, the problem may be with the replacement assembly's sealing surface or closing mechanism.
Two questions
1. What is the part number of the new dispenser assembly you installed? I'd like to verify that it's the correct updated version.
2. When you gently push the flapper closed by hand, does the light disappear completely, or can you still see light around the edges?
Those two answers will help determine whether the problem is an adjustment, a defective replacement assembly, or a separate sealing issue.