Darrin March 20, 2016 for Model Number GLWS1349AS1 All I have is hot water if it is on warm it is just hot on hot just hot switched to cold nothing ? Not sure if it is switch or water inlet valve any ideas ??
1 Answer Hello Darrin. It sounds like the valve 134190200 is bad and will need to be replaced on the unit. Read More...
Richard June 21, 2015 for Model Number GLWS1649AS1 When I use the cold water setting water barley trickles out. This does not happen for hot water as it flows normally. I checked the flow coming into the washer and that is fine. I am assuming there is a solenoid that is not opening the cold water valve in the machine all the way or is it the switch that controls the water temp? Thanks for any help.
1 Answer Hello Richard. You will need to check the screens for the cold water on the unit. If they are not clogged, then you will need to order and replace the water valve 134190200 on the unit. Read More...
Robert May 27, 2014 for Model Number FWSB55RGSO Hello, I've recently change my Water Inlet Valve Assembly. The problem I'm still having is ONLY the cold water is running constantly during it's cycle. To resolve this problem, I must move the knob for the load size, then the cycle starts. It will do the same in rinse cycle. What other part should I replace? Again, it's only the cold. Hot & warm work fine. Thank You.
1 Answer Hello Robert. Check the pressure hose and if it is good, replace the pressure switch 134680100 on the unit. Read More...
Janis November 05, 2012 for Model Number 134409000 Is this a hard part to install? I would like to do it myself.
1 Answer Hello Janis, This is not a hard part to install. You would unplug unit and take rear cover off control panel. Pull the knob off. Remove one wire at a time and connect to new part to ensure proper wiring. Read More...
Dave November 27, 2011 for Model Number FWS446GHS1 What does this switch control? When it is filling up with water it seems like it just keeps filling and leaks out on floor.
1 Answer Hello Dave. The switch 134409000 is for the temperature. If the pressure switch 134680100 is bad, it will cause the water to overflow. If you have to turn the water off at the shut off, you will need to replace the water valve 134190200. Hope this helps. Read More...