1 Answer

Darrel,

It sounds like the defrost drain may be clogged and you will want to remove the back wall of the freezer to make sure that the drain is not clogged and pull the drain from the back of the unit and clean it out.

Read More...

1 Answer

Andy,

This would be a defrost issue and would need to test the defrost thermostat and defrost heater for continuity. If these check good for continuity then the issue will most likely be caused by a faulty defrost timer.

Read More...

1 Answer

Raymond,

If there was water coming out of the door during defrost and the floor of the freezer has ice on it then you will just need to clean out the drain and flush with hot water. If there is water coming from the dispenser assembly non stop then the most likely cause would be a faulty water valve.

Read More...

1 Answer

Hello Ken. Check and see if the unit is frosted up. If so, it will cause you to think the fans are doing this. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello Kevin. The temp control WR09X20002 or the defrost timer WR09X10041 can cause the fan motor not to run, but if one of these are bad, the compressor will not run also. They both are located in the control panel.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google