1 Answer KC,Pull the unit out and locate the compressor in the rear lower cover. Follow the wire harness connected to the compressor to find the overload. Disconnect power, remove the harness and replace the part. Read More...
Krystal September 12, 2023 for Model Number MTX17KAZDRWH I had a power failure and now my compressor will not start back up. Is this the part I need?
1 Answer Krystal,If the part has 120 VAC to it and the compressor will not run then most likely it would need to be replaced as long as the compressor is ok. Read More...
1 Answer Mark, This overload can be tested by doing a continuity test by putting one lead in the hole of it and touching the other lead to the terminal. If it does not read continuity then it is faulty. Read More...