Jeff July 30, 2016 for Model Number Model #: JGB250SET2SS Serial #: TV218359p the existing spark module is: CUSTOMER CODE: 222D6270P001; B200044-63. Will Spark Module Svc Kit Part Number WB13K10054 (AP5646437) fit? Looks they are different. WB13K10054 is larger than existing one, and color is also different.
1 Answer Jeff, Yes the spark module service kitWB13K10054 is the correct spark module for your unit. Read More...
David March 09, 2016 for Model Number jgb281der4bb I purchased a spark module wb13k10054 but it much different from the one on now (customer #222d6270p001. The hook ups are different(connecting tabs). Will this work and how do I make sure I'm connecting it correctly? Thanks
1 Answer Hello David. The modules have markings on them. L is for the hot wire. N is for neutral. The ignitor wires can go to any of the ignitor terminals on the module. Read More...
Rick December 13, 2015 for Model Number JGB250DET1WW I was given a part number for GE MODEL JGB250DET2WW as #AP5646437 the picture shows Type: #BK0044-56 my Type shows #B200044-53 is this the right part and will it mount if it is different?
1 Answer Rick, Yes this spark module WB13K10054 is the correct module for your unit and will mount the same as the original. Read More...
Steve June 10, 2015 for Model Number JFB281SER4SS If I purchase WB13K10054, can I install only the spark module or will I have to replace the wires to the burners as well? Asked another way, will the original OEM wires mate to the spark module in the service kit? Thanks, Steve
1 Answer Steve, It is recommended to install the wires along with the spark module when installing this kit. Read More...
Mike September 28, 2014 for Model Number ge gas range JGB281DER4WW When I turn on the knobs to light the burners on my Ge gas range, only 2 burners have spark. The 2 right burners have spark and light correctly. The 2 left burners have no spark but do have gas and will light if I use a match. I am planning on ordering part AP 5646437 to correct the problem. Do you think I am on the right path. Thank you
1 Answer Mike, You would be on the right path but you would also want to check the spark switches for the left side. The switches in the light position should have continuity and if they do not then they would be faulty. If he switches have continuity but still no spark then the spark module WB13K10054 would be the issue. Read More...